Filter Results By:

Products

Applications

Manufacturers

Showing results: 46 - 60 of 86 items found.

  • Dispersion

    TQC B.V.

    Dispersions are often used in latex wall paints, which can thus be diluted with water. The homogenity of a dispersion depends on size and weight of particles. To determine the size of particles the use of a Fineness of Grind gauge or grindometer is needed. For proper mixing and / or stirring a variety of laboratory and industrial tools are available depending on volume or capacity.

  • Zeta Streaming Potential

    ZETA-check - Particle Metrix GmbH

    Particle interface potentials like the oscillating zeta streaming potential measured in the ZETA-check, represent the level of electrostatic repulsion between particles. The potential is generated by ionic end groups on particles and macro-molecules, respectively. With ZETA-check, the state of the actual charge of dispersions and macromolecular solutions is obtained within seconds. Solutions and dispersions from 0.3 nm up to 100 µm particle size qualify for measurement.

  • Benchtop Small Angle X-ray Scattering (SAXS) Instrument

    NANOPIX mini - Rigaku Corp.

    Non-destructive measurement of particle size and size distribution.Rigaku NANOPIX mini is the world’s first benchtop small angle X-ray scattering (SAXS) system that is engineered to deliver automatic nanoparticle size distribution analysis for both quality control (QC) and research and development (R&D) applications. Nanoparticle size, size distribution, and particle shape are the key pieces of information obtained from SAXS. Samples may range from solutions, suspensions or slurries to solid plastics, rubbers or polymers.

  • Particle Sensor

    HPM Series - Honeywell Sensing & Control

    The Honeywell HPM Series Particle Sensor is a laser-basedsensor which uses the light scattering method to detectand count particles in the concentration range of 0 g/m3to 1,000 g/m3 in a given environment. A laser light sourceilluminates a particle as it is pulled through the detectionchamber. As particles pass through the laser beam, the lightsource becomes obscured and is recorded on the photo orlight detector. The light is then analyzed and converted toan electrical signal providing particulate size and quantity tocalculate concentrations in real time. The Honeywell particlesensor provides information on the particle concentration forgiven particle concentration range.

  • Aerodynamic Particle Sizer (APS)

    Spectrometer 3321 - TSI Inc.

    The Aerodynamic Particle Sizer® 3321 (APS™ spectrometer) provides high-resolution, real-time aerodynamic measurements of particles from 0.5 to 20 microns. These unique particle sizers also measures light-scattering intensity in the equivalent optical size range of 0.37 to 20 microns. By providing paired data for each particle, the APS spectrometer opens up exciting new possibilities for those interested in studying the makeup of an aerosol.

  • Engine Exhaust Particle Sizer

    Spectrometer 3090 - TSI Inc.

    The Engine Exhaust Particle Sizer 3090 (EEPS™) spectrometer measures the size distribution of engine-exhaust particle emissions in the range from 5.6 to 560 nm with the fastest time resolution available. Users can visualize and study the dynamic behavior of particle emissions that occur during transient test cycles, during the first few seconds of a cold start, or during regeneration of a particle trap or diesel particulate filter (DPF).

  • Dynamic Image Analysis (DIA)

    CAMSIZER - Retsch Technology GmbH

    Dynamic Image Analysis (DIA) is a modern high-performance method for the characterization of particle size and particle shape of powders, granules and suspensions. Retsch Technology's optical analyzers CAMSIZER P4 and CAMSIZER X2 are based on this technology, covering a measuring range from 0.8 m to 30 mm.

  • Particle Analyzer

    CAMSIZER X2 - Retsch Technology GmbH

    The quality control of fine powders can be substantially improved with the new CAMSIZER X2: More precise and faster analysis of particle size and particle shape helps to improve the product quality, reduce rejects and save labor costs, energy and raw materials. The design of the CAMSIZER X2 is based on the well-proven optical particle measurement system Camsizer but is optimized for finer samples (from 0.8 m to 8 mm).

  • Laser Diffraction Systems

    Microtrac

    Since the release of the 7991 in 1974, the first commercially available particle size analyzer, Microtrac has been at the forefront of Laser Diffraction technology. By continuously improving the instrument technology, Microtrac offers customers a robust portfolio of Laser Diffraction instruments that’s ideal for particle sizing and characterization.

  • On-board Emissions Measurement System

    OBS-ONE PN Unit - HORIBA, Ltd.

    The OBS-ONE PN unit is an on-board emissions measurement system for analyzing the solid particle number concentration within the specified particle size range under real-world driving conditions. The unit uses a condensation particle counter which is recommended principle by the Particle Measurement Programme (PMP), one of working groups affiliated with UNECE.The PN unit combines with the GAS unit to measure the specified exhaust gas components, along with the exhaust gas flow rate, the GPS position, and the atmospheric conditions (temperature, humidity, pressure).

  • Video Particle Counter with built-in Camera

    VPC300 - MRC ltd.

    Particle Counter with unique built-in camera for capturing videos & photosthat are stored onto internal memory or a micro SD card. The VPC300 canmeasure up to 6 channels of particle sizes plus Air Temperature and RelativeHumidity. Use the included software to generate reports with videos, photos,and data points.

  • Video Particle Counter with Built-In Camera

    Extech VPC300 - Extech Instruments Corporation

    The VPC300 is a Video Particle Counter with built-in Camera. Measures up to 6 channels of particle sizes plus air temperature and relative humidity. Used for capturing videos and photos that are stored onto internal memory or a micros card. The VPC300 can measure up to 6 channels of particle sizes plus air temperature and relative humidity. Use the included software to generate reports with videos, photos and data points. Complete with NIST-traceable calibration certificate, Universal AC Adapter/Charger with multiple plugs, USB cable, PC software, tripod, filter, 7.4V NiMH battery and a hard, protective case.

  • Nanoparticle Analyzer

    nanoPartica SZ-100V2 Series - HORIBA, Ltd.

    A highly advanced analyzer solves the mysteries of the nano-world. A single device analyzes the three parameters that characterize nanoparticles: particle size, zeta potential, and molecular weight.

  • Abbreviated Impactor Measurement Equipment

    AIM - MSP Corporation

    The Abbreviated Impactor Measurement (AIM) Method implies using a shorter process to characterize aerodynamic size. It has been promoted as an alternative to the labor-intensive full resolution cascade impactor methodology for APSD (aerodynamic particle size distribution) testing.

  • Multi-Laser Nanoparticle Tracking Analysis (NTA)

    ViewSizer 3000 - HORIBA, Ltd.

    Exosomes? Virus? Nanoparticle? Use multiple lasers for complete, detailed analysis of all the particles in your sample.Exosomes, viruses, and nanoparticles all have wide size distributions which defeat traditional Nanoparticle Tracking Analysis (NTA) analyzers. The ViewSizer 3000 features simultaneous measurement with three lasers to collect the most accurate distribution and concentration information over a wide range of sizes within the same sample. Where the signal from a particle is too bright and saturates the detector from one laser, the software automatically uses data from a lower power laser to ensure the most accurate size and concentration information. On the other hand, when scattering from one laser is too weak for detection, the software uses data from a higher power laser to accurately track the particle.